#1. The ratio of mass rate of water feeding to the steam-generating tubes to the mass flow rate of generated steam is defined as

  • Steam generation ratio: This is the ratio of the mass flow rate of steam generated to the mass flow rate of fuel burned.
  • Turndown ratio: This is the ratio of the minimum operating load to the maximum operating load.
  • Evaporation ratio: This is the ratio of the mass of water evaporated to the mass of fuel burned.

#2. In a working Boiler, maximum pressure exits in

in question asked in a working boiler, Feed lines of boiler is not a part of boiler, but in this line pressure is maximum so,

pressure reducing in accordance

feed lines of boiler>blow down lines of boiler>boiler drum> steam lines of boiler

#3. What should be the silica percentage in superheated steam for efficient operation of steam turbines?

#4. How many kg of CO2 are produced in complete combustion of 16 kg of Methane?

#5. Size of boiler tube is specified by

#6. The pH of feed water in which hydrazine dosing is practiced

#7. Which is not desirable property of fuel

#8. Calculate the boiler efficiency (in percentage) of certain boiler if Evaporation ratio is 5. Enthalpy difference between saturated steam and feed water is 1500 kcal/kg. Given the Gross Calorific Value of fuel is 10,000 kcal/kg of fuel.

#9. The enthalpy of steam at 170 degree Celsius with wetness fraction of 0.25 would

#10. Which of the following would have the maximum resistance of heat transfer to a steam pipe when indirect heating is carried out (the product and steam does not intermix)

#11. The power output is least for which

#12. For safe boiler with evaporation capacity of 90 tons/hr, two safety valves is to the fitted with atleast evaporation capacity

#13. The blow down for Safety valve is given by

#14. The principle of Mechanical Deaeration is based on which of the following scientific laws?

#15. Which of the following is the most suitable candidate to act as Emergency Shutdown valve?

#16. The safety valve of Superheater is set at a pressure the__________ safety valve of boiler drum of the same boiler.

#17. In which of the following units can a boiler’s rating be described?

#18. Which of the following will be ideal for heat transfer in a heat exchanger

#19. Stream trap is fitted at

#20. Boiler drum and other cylindrical component having internal diameter greater than 600 mm shall be hydraulically tested at

#21. Water temperature at hydraulic testing of boiler shall be in the range of

#22. I D fan is always located between

#23. Safety valve having seat diameter not less than 32 mm should reset at

#24. FBCB means

#25. Evaporation of 2000 kg of water per hour from and at 100° C is

#26. While applying hydraulic test to boiler, test pressure to be maintained for

#27. Inspecting authority certificate of inspection during construction as per IBR (Regulation 4(c) (1)] issued in

#28. Which data is not required to calculate boiler efficiency by the indirect method

#29. The sulphur retention of Fluidised Bed Combustion boilers is dependent on

#30. At critical point i.e. p = 225.65 kg/cm2, the latent enthalpy of vaporization is

#31. Which of the following can be used as a tube material (without hampering performance and efficiency) of boiler superheater exposed to a maximum flue gas temperature of 1025 °C (Paper-2)

#32. Excessive blow down

#33. Any closed vessel which is used expressly for generating steam under pressure will be covered under Boiler Act 1923 if volumetric capacity of vessel

#34. Phosphate hideout is most evident in boiler tubes with

#35. RLA stands for

#36. For shell type boiler max permitted working pressure is reduced by 5 % when it attains age of

#37. If electric light is used inside a boiler shell or drum voltage shall not exceed

#38. Maximum outlet water temperature of the economiser of high pressure boiler shall be at least,

#39. Thermocouple is used for

#40. Manholes of oval type shall be arranged such that

#41. Minimum Boiler plate thickness specified in IBR 1950 is

#42. As per Indian Boiler Regulation 1950, following is not necessary on a boiler

#43. Following statement is not true for water level indicators

#44. Following statement is not true for Heat Rate

#45. Which of the following statement is not true?

#46. In a Super heater

#47. Which condition leads the boiler starvation

#48. Which type of coal is having highest percentage of fixed carbon?

#49. With reference to demineralization process which one is not true

#50. What does the turbidity in boiler feed water cause?

#51. Equivalent evaporation is the amount of water evaporated in a boiler from and at …..

#52. If a steam sample is nearly in dry condition, then its dryness fraction can be most accurately determined by

#53. A dense white smoke from a chimney indicates

#54. Higher calorific value of fuel assumes that

#55. The draught produced by steel chimney as compared to that produced by brick chimney for the same height is

#56. Following is the advantage of supercritical boilers

#57. As per the Boilers Act, 1923 (as amended in 2007) Following action is not a punishable

#58. Proficiency certificate of engineer can be cancelled permanently if holder,

#59. The function of injector is to

#60. Boiler stays are used to Provide foundation of boiler

Previous
Finish

Related Posts

Explain the types of tube failure that may occur innthe initial stage of boiler operation till stabilization?

During the initial stage of boiler operation, until the system reaches a stable operational phase,Read More

High Pressure Bypass Fast open Condition

Turbine trip GCB open LSR operated Emergency fast open push button pressed Pressure deviation highRead More

FSSS (Furnace Safeguard Supervisory System)

FSSS LOGIC SYSTEM BOILER START- UP SEQUENCE The boiler can be placed in service, initiallyRead More

Leave a Reply