Cooling tower in a thermal power plant

Cooling towers are an important component in a thermal power plant, as they are used to remove the excess heat generated during power generation. Thermal power plants typically use steam turbines to generate electricity, and the steam used in the turbines is generated by heating water in a boiler using fossil fuels such as coal or natural gas.

During the process of generating steam, a large amount of heat is produced, which needs to be removed. Cooling towers are used to remove this excess heat by using evaporative cooling.

In a thermal power plant, the hot water generated in the condenser is pumped to the cooling tower, where it is sprayed over a fill material. As the hot water is sprayed over the fill material, it comes into contact with the cool air entering the tower. This causes some of the water to evaporate, which removes the heat from the water and cools it down. The cooled water is then collected at the bottom of the tower and returned to the condenser to complete the cooling cycle.

There are two main types of cooling towers used in thermal power plants: natural draft cooling towers and mechanical draft cooling towers. Natural draft cooling towers use the natural buoyancy of the warm air rising to draw in cool air from below, while mechanical draft cooling towers use fans to force the air through the tower.

There are two main types of cooling towers used in thermal power plants: natural draft cooling towers and mechanical draft cooling towers. Natural draft cooling towers use the natural buoyancy of the warm air rising to draw in cool air from below, while mechanical draft cooling towers use fans to force the air through the tower.

Proper operation and maintenance of cooling towers in thermal power plants are critical to ensure that the power plant operates efficiently and reliably. Issues such as fouling of the fill material, scaling, corrosion, and algae growth can affect the performance of the cooling tower and reduce its cooling efficiency. Regular maintenance, cleaning, and monitoring of the cooling tower can help prevent these issues and ensure that the power plant operates at its maximum capacity.

Here are some important formulas related to cooling towers:

  1. Cooling Range:
    Cooling range is the difference between the inlet water temperature and outlet water temperature of a cooling tower. A higher cooling range indicates a more efficient cooling tower, as it means that the cooling tower is capable of removing more heat from the process water. It is expressed in degrees Celsius (°C) or degrees Fahrenheit (°F).
    Cooling Range = Inlet Water Temperature – Outlet Water Temperature
  2. Approach:
    Approach is the difference between the outlet water temperature of a cooling tower and the wet bulb temperature of the air entering the tower. A lower approach indicates a more efficient cooling tower, as it means that the cooling tower is able to cool the process water to a lower temperature with less energy consumption. It is expressed in degrees Celsius (°C) or degrees Fahrenheit (°F).
    Approach = Outlet Water Temperature – Wet Bulb Temperature
  3. Range of Cooling Tower:
    Range of Cooling Tower is the difference between the hot water temperature and the cold water temperature.
    Range = Hot Water Temperature – Cold Water Temperature
  4. Water Flow Rate:
    The water flow rate is the rate at which water is flowing through the cooling tower. A higher water flow rate can increase the cooling efficiency of the cooling tower, as it can increase the contact time between the process water and the air. Water Flow Rate is the rate at which water is flowing through the cooling tower. It is expressed in liters per minute (lpm) or gallons per minute (gpm).
    Water Flow Rate = (Total Heat Load)/(Specific Heat of Water x Density of Water x Cooling Range)
  5. Heat Load:
    The heat load is the amount of heat that needs to be removed from the process water. A more efficient cooling tower can remove more heat with less energy consumption, resulting in a lower heat load. Heat Load is the amount of heat that needs to be removed from the process water. It is expressed in kilowatts (kW) or British Thermal Units (BTUs).
    Heat Load = Water Flow Rate x Specific Heat of Water x Cooling Range
  6. Wet Bulb Temperature:
    The wet bulb temperature is the temperature at which water evaporates from a wet surface. The wet bulb temperature is a measure of the cooling efficiency of the cooling tower, as it is an indication of the amount of cooling that can be achieved through evaporative cooling. Wet Bulb Temperature is the lowest temperature that can be achieved by evaporative cooling using water. It is measured using a thermometer with a wet wick around the bulb.
    Wet Bulb Temperature is an indicator of the cooling efficiency of a cooling tower.
  7. Fan Power:
    Fan Power is the power consumed by the fans of the cooling tower. It is expressed in kilowatts (kW) or horsepower (hp).
    Fan Power = (Air Flow Rate x Pressure Drop)/(3.415 x Fan Efficiency)

Related Posts

Explain the types of tube failure that may occur innthe initial stage of boiler operation till stabilization?

During the initial stage of boiler operation, until the system reaches a stable operational phase,Read More

High Pressure Bypass Fast open Condition

Turbine trip GCB open LSR operated Emergency fast open push button pressed Pressure deviation highRead More

FSSS (Furnace Safeguard Supervisory System)

FSSS LOGIC SYSTEM BOILER START- UP SEQUENCE The boiler can be placed in service, initiallyRead More