Category: Uncategorized

 

BOILER FEED PUMP OPERATING INSTRUCTION

PREPARATION FOR STARTING Check the Deaerator is filled to normal working level. Check that the control air and electrical supply are available for the instrumentation, leak off equipment and valve. Check that the recirculation valve and isolating valve are open. Check that all the instrumentation tapping points and isolating valveRead More

DEAERATOR IN THERMAL POWER PLANT

DEAERATOR AN INTRODUCTION Remove dissolved gases. Highest vessel in the system. Used for heating of feed water. Reduce the amount of steam in the system and hence energy flow to the plant. Extraction steam enters from the bottom of the tanks. Steam passes over the water droplets. As the extractionRead More

NATURAL DRAFT COOLING TOWER

Typical power-plant cycles which incorporate the natural-draft hyperbolic cooling tower are shown in the schematics. Note that only 40% of heat-energy input is converted to power in the fossil-fuel plant, while 45% is discharged to condenser cooling water; the remaining 15% is lost up the stack & in the ash.Read More

TURBINE ROLLING

OBJECTIVE OF TURBINE ROLLING:-To bring the unit on load and raised on rated output within optimum time but also without under stress on the turbine components.Warming up and startup of the turbine during various steam condition of or turbine metal temperature condition are given by the manufacturer in the formRead More