Boiler drum level Control

Boiler drum level control in large size boilerBoiler drum level control is a critical aspect of maintaining the safety and efficiency of large size boilers. A boiler drum is a vessel that stores water and steam in a closed system. The drum level must be carefully monitored and controlled to prevent damage to the boiler and ensure that the system operates at optimal efficiency.

There are various methods for controlling the level of the boiler drum. One common method is the use of a level gauge, which is a device that measures the level of water in the drum. This information is then used to adjust the flow of water into the drum to maintain a consistent level.

Another method is to use a control valve to regulate the flow of water into the drum. The valve is controlled by a level controller that continuously monitors the water level and adjusts the valve position accordingly.

In addition to these methods, some large size boilers also use advanced technologies such as ultrasonic sensors and capacitance probes to monitor and control the drum level.

It is important to note that proper maintenance and calibration of the level control system is crucial to ensure accurate and reliable operation. Regular inspections and testing should be conducted to identify any potential issues and prevent system failures.

Three element boiler drum level control system

The three element boiler drum level control system is a popular method for controlling the water level in a boiler drum. This system uses three signals to control the water level:

1:-Steam flow rate
2:-Water flow rate
3:-Drum level


The steam flow rate signal is used to compensate for changes in steam demand. As the demand for steam increases, the steam flow rate signal increases, and the control system responds by increasing the water flow rate to the drum to maintain the desired level.

The water flow rate signal is used to compensate for changes in feedwater supply. As the feedwater flow rate decreases, the water flow rate signal decreases, and the control system responds by reducing.

Related Posts

Explain the types of tube failure that may occur innthe initial stage of boiler operation till stabilization?

During the initial stage of boiler operation, until the system reaches a stable operational phase,Read More

High Pressure Bypass Fast open Condition

Turbine trip GCB open LSR operated Emergency fast open push button pressed Pressure deviation highRead More

FSSS (Furnace Safeguard Supervisory System)

FSSS LOGIC SYSTEM BOILER START- UP SEQUENCE The boiler can be placed in service, initiallyRead More

Comments are Closed